Sheila, Hang
AS port:
| BS | SRM | SRC2 | DC3 | DC4 | CSOFT | CHARD | DSOFT | DHARD | PRM | PR3 | INP1 | |
| Transfer Function, [W/rad] | 7.56e+2 | 1.19e+1 | 4.02e+1 | 2.09e+2 | 0 | 3.37e+1 | 2.64e+1 | 2.50e+2 | 2.04e+2 | 1.38e-2 | 3.13e+1 | 5.92e-3 |
| Demod phase, [deg] | -67 | 30 | 43 | 52 | N/A | -155 | 24 | 111 | -62 | -108 | 17 | -73 |
| Noise floor, [rad/Hz^{1/2}] | 5.4e-13 | 3.4e-11 | 1.0e-11 | 1.96e-12 | inf | 1.2e-11 | 1.6e-11 | 1.6e-12 | 2.0e-12 | 3.0e-8 | 1.3e-11 | 6.9e-8 |
| BS | SRM | SRC2 | DC3 | DC4 | CSOFT | CHARD | DSOFT | DHARD | PRM | PR3 | INP1 | |
| Transfer Function, [W/rad] | 6.94e+2 | 3.24e+1 | 3.58e+1 | 9.15e-1 | 2.12e+2 | 5.44e+1 | 4.52e+1 | 2.32e+2 | 1.85e+2 | 1.7e-2 | 5.65e+1 | 4.43e-3 |
| Demod phase, [deg] | -91 | -168 | 25 | -40 | 3 | -8 | 172 | 88 | -100 | 49 | -170 | 116 |
| Noise floor, [rad/Hz^{1/2}] | 8.1e-13 | 1.74e-11 | 1.6e-11 | 6.2e-10 | 2.7e-12 | 1.0e-11 | 1.2e-11 | 2.4e-12 | 3.1e-12 | 3.3e-8 | 1.0e-11 | 1.3e-7 |
| BS | SRM | SRC2 | DC3 | DC4 | CSOFT | CHARD | DSOFT | DHARD | PRM | PR3 | INP1 | |
| Transfer Function, [W/rad] | 2.01e+2 | 2.83e+1 | 4.34e+1 | 1.80e+2 | 1.28e+0 | 1.83e+2 | 2.47e+2 | 1.58e+2 | 2.78e+3 | 1.66e-3 | 4.76e+0 | 1.38e-3 |
| Demod phase, [deg] | -48 | -86 | -92 | -91 | 92 | 45 | 44 | -115 | -87 | 133 | -26 | 63 |
| Noise floor, [rad/Hz^{1/2}] | 3.4e-13 | 2.4e-12 | 1.5e-12 | 3.7e-13 | 5.2e-11 | 3.7e-13 | 2.7e-13 | 4.24e-13 | 2.4e-14 | 3.9e-8 | 1.4e-11 | 4.9e-8 |
| BS | SRM | SRC2 | DC3 | DC4 | CSOFT | CHARD | DSOFT | DHARD | PRM | PR3 | INP1 | |
| Transfer Function, [W/rad] | 1.43e+2 | 3.75e+1 | 2.00e+1 | 8.57e+0 | 1.52e+2 | 2.29e+2 | 2.92e+2 | 1.55e+2 | 2.53e+3 | 2.00e-3 | 1.37e+1 | 1.85e-3 |
| Demod phase, [deg] | 132 | 87 | -104 | 86 | -91 | -111 | -113 | 71 | 87 | -62 | 112 | -108 |
| Noise floor, [rad/Hz^{1/2}] | 3.7e-13 | 1.4e-12 | 2.6e-12 | 6.0e-12 | 3.4e-13 | 2.2e-13 | 1.8e-13 | 3.3e-13 | 2.0e-14 | 2.6e-8 | 3.7e-12 | 2.8e-8 |
| BS | SRM | SRC2 | DC3 | DC4 | CSOFT | CHARD | DSOFT | DHARD | PRM | PR3 | INP1 | |
| Transfer Function, [W/rad] | -9.8e+1 | -2.1e+1 | -3.1e+1 | -1.3e+2 | 0 | 4.4e+1 | 3.5e+1 | -4.8e+1 | -9.8e+2 | 0 | 1.7e+0 | 5.2e-4 |
| Noise floor, [rad/Hz^{1/2}] | 2.2e-12 | 1.0e-11 | 7.1e-12 | 1.7e-12 | inf | 5.0e-12 | 6.3e-12 | 4.6e-12 | 2.2e-13 | inf | 1.3e-10 | 4.2e-7 |
| BS | SRM | SRC2 | DC3 | DC4 | CSOFT | CHARD | DSOFT | DHARD | PRM | PR3 | INP1 | |
| Transfer Function, [W/rad] | 4.9e+1 | 2.3e+1 | -1.3e+1 | 2.2e0 | -1.0e2 | -4.5e+1 | 0 | 3.6e+1 | 7.3e+2 | -2.5e-3 | 1.2e+1 | 1.6e-3 |
| Noise floor, [rad/Hz^{1/2}] | 5.7e-12 | 1.2e-11 | 2.2e-11 | 1.3e-10 | 2.8e-12 | 6.2e-12 | inf | 7.8e-12 | 3.8e-13 | 1.1e-7 | 2.3e-11 | 1.8e-7 |
| BS | SRM | SRC2 | DC3 | DC4 | CSOFT | CHARD | DSOFT | DHARD | PRM | PR3 | INP1 | |
| Transfer Function, [W/rad] | 4.9e+1 | 0 | 0 | -2.2e0 | 0 | 0 | 0 | 0 | 0 | 0 | 1.0e+0 | 0 |
| Noise floor, [rad/Hz^{1/2}] | 3.3e-11 | inf | inf | 7.4e-10 | inf | inf | inf | inf | inf | inf | 1.6e-9 | inf |
| BS | SRM | SRC2 | DC3 | DC4 | CSOFT | CHARD | DSOFT | DHARD | PRM | PR3 | INP1 | |
| Transfer Function, [W/rad] | 0 | 1.5e+0 | 0 | 0 | -6.7e+0 | 0 | 0 | 0 | 0 | 0 | 3.6e-1 | 0 |
| Noise floor, [rad/Hz^{1/2}] | inf | 8.6e-10 | inf | inf | 1.9e-10 | inf | inf | inf | inf | inf | 3.6e-9 | inf |
| BS | SRM | SRC2 | DC3 | DC4 | CSOFT | CHARD | DSOFT | DHARD | PRM | PR3 | INP1 | |
| Transfer Function, [W/rad] | 2.1e+1 | 8.8e+0 | -1.6e+1 | 6.3e-1 | 0 | -1.1e+1 | 1.9e+1 | 5.7e+0 | 1.7e+2 | -1.5e-3 | 8.3e+0 | 8.1e-4 |
| Noise floor, [rad/Hz^{1/2}] | 2.6e-12 | 6.3e-12 | 3.5e-11 | 8.8e-11 | inf | 5.0e-12 | 2.9e-12 | 9.7e-12 | 3.2e-13 | 3.7e-8 | 6.7e-12 | 6.8e-8 |
At REFL port:
TR (calibration of the pd may be quite off, but the noise floor in rad/sqrt{Hz} should be accurate):