patrick.thomas@LIGO.ORG - posted 13:41, Thursday 17 March 2016 - last comment - 15:00, Thursday 17 March 2016(26112)
Starting WP 5779
Starting with h1conlog1-replica at ~ 20:41 UTC. Stopping MySQL replication slave.
Comments related to this report
patrick.thomas@LIGO.ORG - 15:00, Thursday 17 March 2016 (26113)
h1conlog1-replica:

Stopped replication slave
Ran 'sudo apt-get update'
Ran 'sudo apt-get dist-upgrade'
Dave installed host based authentication
Ran 'sudo shutdown -r now'
Started replication slave


h1conlog1-master:

Ran 'ps -elf | grep conlog'
0 S cdsadmin 21958 21937  0  80   0 -  2936 pipe_w 14:10 pts/2    00:00:00 grep --color=auto conlog
5 S root     26282     1  0  80   0 - 16298 poll_s Jan26 ?        00:00:00 sudo -b -E -u conlog /opt/conlog/bin/linux-x86_64/conlog
4 S conlog   26283 26282  4  80   0 - 1112555 hrtime Jan26 ?      2-13:01:59 /opt/conlog/bin/linux-x86_64/conlog
Ran 'sudo pkill -9 26282' (no effect)
Ran 'sudo pkill -9 26283' (no effect)
Ran 'sudo kill 26283' (worked)

Ran sudo 'apt-get update'
Ran sudo 'apt-get dist-upgrade'
Ran script on opsws10 to regenerate channel list while waiting for dist-upgrade to finish.
Dave installed host based authentication
Ran 'sudo shutdown -r now'
Ran 'sudo -b -E -u conlog /opt/conlog/bin/linux-x86_64/conlog'
Ran 'sudo /opt/conlog/bin/linux-x86_64/conlog_admin use /ligo/lho/data/conlog/h1/input_pv_list/pv_list.txt' (added 100726 channels)
Waiting for 1736 channels to connect. These appear to be Beckhoff channels. I can caget at least one of them from h1conlog1-master.