ITMX green camera view has changed

Today we noticed that there were some unidentified bright dots on the ITMX green camera (cam22) which had not existed before. The positions of the dots were found to be functions of the alignment of the ITMX compensation plate for some reason. We temporarily applied a large offset (-530 urad in yaw) on the compensation plate to minimize the effect on the centroid fitting. We tried moving the dots by moving the large suspended optics, but none of them showed dependencies. We have no idea why we started having thees dots. We will try using the camera as it is since the dots seem to be insensitive to the arm cavity alignment.

Images attached to this report
Comments related to this report
gerardo.moreno@LIGO.ORG - 16:14, Monday 21 March 2016 (26172)
Cameras where repositioned after viewport install. See here https://alog.ligo-wa.caltech.edu/aLOG/index.php?callRep=26068
daniel.sigg@LIGO.ORG - 16:55, Monday 21 March 2016 (26175)

The compensation plates seem to be responsible for the etalon effect. The green spots disappear, when the green beam is shuttered at the end.

stefan.ballmer@LIGO.ORG - 20:54, Monday 21 March 2016 (26178)

Updated the camera configuration files (centroid and radius) and reference positions. Attached are snapshots and the config files.