Reports until 01:39, Tuesday 22 March 2016
H1 ISC
stefan.ballmer@LIGO.ORG - posted 01:39, Tuesday 22 March 2016 - last comment - 01:49, Tuesday 22 March 2016(26182)
ASC oscillations at P>10W

Jenne, Sheila, Kiwamu, Hang, Stefan

We tried to monitor the AS WFS gains during powerup. However, we didn't see any sign flips. Nevertheless, a combination of SOFT and SCR1 loops ran away anyway.

On the next attempt we again observe the onset of a 0.4Hz oscillation in pitch, which, depending on alignment, starts around 13W-15W, and grows until lock-break.

Jenne tried to move the soft offsets around to see whether there are alignments that are less suceptible to the 0.4Hz oscillation - not much luck.

Looking at the OPLEVs we noticed that mostly the xarm pitch is moving during power-up (but too slow for radiation pressure effects). Note that during this the soft loop error signals are kept zero, which suggests some non-linearity in the X QPDs.

Comments related to this report
jenne.driggers@LIGO.ORG - 01:49, Tuesday 22 March 2016 (26183)

One last attempt:  We opened the SOFT loops, then went to 10W.  We still get our "favorite" oscillation.  We'll look at some lockloss plots when we're more awake.