SUS FASTIMON and NOISEMON channel work today - SUSAUX model restarts

Flip flopping between the need to use FASTIMONs OR NOISEMONS for a variety of commissioning or DETCHAR reasons (but not being able to support both sets of channels) today we reverted a small portion of the work towards integrating the FASTIMONs into QUAD-land from alog 25329.  Today we put the NOISEMONs back into the BS and QUAD models, keeping their original data rates and made the FASTIMONS commissioning frames only.  This required restarts of the h1susauxb123, h1susauxex, and h1susauxey computers.

 

The SUS AUX Channel Monitor medms then had broken links which I partially fixed.  I fixed the readback channel, but the long colored bit thing associated with every one of these channels (holds the same info as the read back) is a pain in the whooo to change so will have to wait until I can regrow some patience.

Comments related to this report
betsy.weaver@LIGO.ORG - 08:58, Wednesday 30 March 2016 (26332)

I've committed these SUSAUX model changes and medm edits to SVN.