Displaying report 1-1 of 1.
Reports until 16:47, Tuesday 29 March 2016
H1 SEI
hugh.radkins@LIGO.ORG - posted 16:47, Tuesday 29 March 2016 - last comment - 21:31, Wednesday 30 March 2016(26321)
LHO HAM ISI FrontEnds restarted to give SUSPOINT Euler Motion

WP 5799 FR 4694 (PKA II 1193)

Continuing the offload of SUS calculating the SUSPOINT motion from ISI GS13 cartesian motion, this has ISI doing the calculating.  We'll stop the SUS doing the calcs as soon as we confirm that DetChar is happy with the ISI numbers.

All the HAM models were rebuilt & installed and FrontEnds restarted.  safe and OBSERVE.snaps were checked and updated (lots of new channels.)

No issues with HAM ISIs reisolating.

Medm editing is ongoing for the SUSPOINT.  Each medm is custom for the number of suspensions.  HAM6 and HAM2 still need to be built.

Along these lines, the BSC Models were adjusted to put the SUSPOINT on IPC and at ENDY, the BRS was added as at ETMX.

SVN COMMITS:

hugh.radkins@opsws1:models 0$ svn commit -m "HAM SUSPOINT calcs moved to ISI and BSC SUSPOINT calcs added to IPC and BRS at ETMY"
Sending        models/h1isibs.mdl
Sending        models/h1isietmx.mdl
Sending        models/h1isietmy.mdl
Sending        models/h1isiham2.mdl
Sending        models/h1isiham3.mdl
Sending        models/h1isiham4.mdl
Sending        models/h1isiham5.mdl
Sending        models/h1isiham6.mdl
Sending        models/h1isiitmx.mdl
Sending        models/h1isiitmy.mdl
Transmitting file data ..........
Committed revision 12961.
hugh.radkins@opsws1:models 0$ pwd
/opt/rtcds/userapps/release/isi/h1/models

hugh.radkins@opsws1:hamisi 0$ svn commit -m "Added suspension OPTICs for medm generation"
Sending        hamisi/H1_isiham2_overview_macro.txt
Sending        hamisi/H1_isiham3_overview_macro.txt
Sending        hamisi/H1_isiham4_overview_macro.txt
Sending        hamisi/H1_isiham5_overview_macro.txt
Sending        hamisi/H1_isiham6_overview_macro.txt
Transmitting file data .....
Committed revision 12962.
hugh.radkins@opsws1:hamisi 0$ pwd
/opt/rtcds/userapps/release/isi/h1/medm/hamisi


hugh.radkins@opsws1:burtfiles 0$ svn commit -m "Update snaps for SUSPOINT & commissioning"
Sending        burtfiles/h1isibs_down.snap
Sending        burtfiles/h1isibs_safe.snap
Sending        burtfiles/h1isietmx_safe.snap
Sending        burtfiles/h1isietmy_OBSERVE.snap
Sending        burtfiles/h1isietmy_safe.snap
Sending        burtfiles/h1isiham2_safe.snap
Sending        burtfiles/h1isiham3_safe.snap
Sending        burtfiles/h1isiham4_OBSERVE.snap
Sending        burtfiles/h1isiham4_safe.snap
Sending        burtfiles/h1isiham5_OBSERVE.snap
Sending        burtfiles/h1isiham5_safe.snap
Sending        burtfiles/h1isiham6_safe.snap
Sending        burtfiles/h1isiitmx_safe.snap
Sending        burtfiles/h1isiitmy_OBSERVE.snap
Sending        burtfiles/h1isiitmy_safe.snap
Transmitting file data ...............
Committed revision 12963.
hugh.radkins@opsws1:burtfiles 0$ pwd
/opt/rtcds/userapps/release/isi/h1/burtfiles
 

I'll commit the medm adls once I'm finished with them.

Comments related to this report
jeffrey.kissel@LIGO.ORG - 21:31, Wednesday 30 March 2016 (26350)
A full description of the changes committed about can be found in G1600795.
Displaying report 1-1 of 1.