Displaying report 1-1 of 1.
Reports until 09:34, Monday 04 April 2016
H1 SEI
cheryl.vorvick@LIGO.ORG - posted 09:34, Monday 04 April 2016 (26418)
SEI in-vac T240 mass position check

Results are that three proof masses are out of range - I've emailed Hugh to make aware.

Averaging Mass Centering channels for 10 [sec] ...


There are 3 T240 proof masses out of range ( > 0.3 [V] )!
ETMX T240 2 DOF X/U = -0.387 [V]
ETMX T240 2 DOF Y/V = -0.399 [V]
ITMY T240 3 DOF Z/W = -0.303 [V]


All other proof masses are within range ( < 0.3 [V] ):
ETMX T240 1 DOF X/U = 0.041 [V]
ETMX T240 1 DOF Y/V = 0.063 [V]
ETMX T240 1 DOF Z/W = 0.083 [V]
ETMX T240 2 DOF Z/W = -0.251 [V]
ETMX T240 3 DOF X/U = 0.063 [V]
ETMX T240 3 DOF Y/V = -0.13 [V]
ETMX T240 3 DOF Z/W = 0.027 [V]
ETMY T240 1 DOF X/U = 0.011 [V]
ETMY T240 1 DOF Y/V = -0.069 [V]
ETMY T240 1 DOF Z/W = -0.02 [V]
ETMY T240 2 DOF X/U = -0.192 [V]
ETMY T240 2 DOF Y/V = 0.011 [V]
ETMY T240 2 DOF Z/W = 0.123 [V]
ETMY T240 3 DOF X/U = -0.028 [V]
ETMY T240 3 DOF Y/V = -0.026 [V]
ETMY T240 3 DOF Z/W = 0.071 [V]
ITMX T240 1 DOF X/U = -0.197 [V]
ITMX T240 1 DOF Y/V = 0.24 [V]
ITMX T240 1 DOF Z/W = 0.186 [V]
ITMX T240 2 DOF X/U = 0.201 [V]
ITMX T240 2 DOF Y/V = 0.244 [V]
ITMX T240 2 DOF Z/W = 0.227 [V]
ITMX T240 3 DOF X/U = -0.091 [V]
ITMX T240 3 DOF Y/V = 0.186 [V]
ITMX T240 3 DOF Z/W = 0.212 [V]
ITMY T240 1 DOF X/U = 0.165 [V]
ITMY T240 1 DOF Y/V = 0.027 [V]
ITMY T240 1 DOF Z/W = 0.095 [V]
ITMY T240 2 DOF X/U = 0.166 [V]
ITMY T240 2 DOF Y/V = 0.259 [V]
ITMY T240 2 DOF Z/W = 0.184 [V]
ITMY T240 3 DOF X/U = 0.037 [V]
ITMY T240 3 DOF Y/V = 0.194 [V]
BS T240 1 DOF X/U = 0.033 [V]
BS T240 1 DOF Y/V = 0.049 [V]
BS T240 1 DOF Z/W = 0.178 [V]
BS T240 2 DOF X/U = 0.12 [V]
BS T240 2 DOF Y/V = 0.196 [V]
BS T240 2 DOF Z/W = 0.205 [V]
BS T240 3 DOF X/U = 0.089 [V]
BS T240 3 DOF Y/V = 0.074 [V]
BS T240 3 DOF Z/W = -0.026 [V]


Assessment complete.

This closes FAMIS task 4367.
 

Displaying report 1-1 of 1.