Extra Filter Banks for SUSPOINT path added; IPC removed from H1OAF Model
J. Kissel, D. Barker
WP #5812

I'm continuing to work on filling out and debugging the recently installed SUSPOINT path (see LHO aLOGs 26363, 26321, 26320). 

I realized the part of that path which resides inside the OAF front-end model which projects the optic's Longitudinal displacement into the IFO Cavity Basis will need AI filtering for the corner station IPC channels (the ISI models send at 4096 Hz and the OAF model receives at 16384 Hz). Where there had previously only been test points and epics outputs to monitor the received channels, there are now full filter banks. Screens and details of filtering to come.

Also, while playing with the OAF model, Dave suggested we get rid of some more unused IPC connections. So, the "CONN" block -- some vestigial attempt at a monitoring system for the inter-process communication -- and its corresponding IPC senders (on of each flavor, Shared Memory SHMEM, Dolphin PCIe, Reflected Memory RFM) which had no receivers, have been removed. Attached is a screen shot of the block and senders we removed.

The latest version of the h1oaf model has been committed to the svn repo.

This required a frame-builder restart, but we've made no change to the DAQ channel list.