SUSPOINT to CAVITY BASIS Projection Installation Complete
J. Kissel

I've finished generating the MEDM screens for the SUSPOINT to CAVITY BASIS projections, filled out the infrastructure with the appropriate 4k to 16k anti-imaging filters, and populated the EUL2IFO matrix as per T1500610.

I saw some suspicious behavior from an initial test of the signal flow (i.e. by taking point to point transfer functions across the network), so I don't want to declare victory just yet, but we've never been closer.

Attached are screen caps of the new MEDM screens. You can find the screens from the site map under the light-blue SEI button under the "MAIN" section with the rest of the stuff that's IFO location independent.