Displaying report 1-1 of 1.
Reports until 10:30, Friday 08 April 2016
H1 AOS
jim.warner@LIGO.ORG - posted 10:30, Friday 08 April 2016 (26496)
HAM6 ISI looks OK

Corey and I did the last few ISI items this morning in HAM6. Check for tools, wiped down areas where people were working, pulled the septum cover, unlocked the ISI and closed the chamber. While we were doing that Evan, JeffK and Fil checked the operation of the beam diverter and fast shutter (Jeff just alogged that). I've now taken closeout ISI measurements and the ISI looks ok. I think my measurements are made a little noisy by high purge flow in the chamber, so I may take longer measurements after the chamber closes. But I think we are good to put doors on.

Images attached to this report
Displaying report 1-1 of 1.