Kyle, Gerardo, Jeff B., Chandra East door was installed on Thursday. North and South doors were installed today. Two of three are torqued. We will torque the South and start the rough pump down after late lunch. NOTES: 1. North door has a questionable scratch along the o-ring sealing surfaces (but not wide enough to cross both o-rings at same time, we think). Scratch is in fourth quadrant (when looking at door). 2. Inner o-ring of South door was bad. We replaced with one from 1998 processed stock. We will leak check all doors before COB today.
Excellent - although east door was installed Thursday. or -Y door as some would prefer.