HAM6 doors ON
Kyle, Gerardo, Jeff B., Chandra

East door was installed on Thursday. North and South doors were installed today. Two of three are torqued. We will torque the South and start the rough pump down after late lunch. 

NOTES:  

1. North door has a questionable scratch along the o-ring sealing surfaces (but not wide enough to cross both o-rings at same time, we think). Scratch is in fourth quadrant (when looking at door).
2. Inner o-ring of South door was bad. We replaced with one from 1998 processed stock. 

We will leak check all doors before COB today.

Comments related to this report
john.worden@LIGO.ORG - 15:36, Friday 08 April 2016 (26504)

Excellent - although east door was installed Thursday. or -Y door as some would prefer.

chandra.romel@LIGO.ORG - 16:01, Friday 08 April 2016 (26505)
Fixed the log entry, John. :) 

Kyle has photos of the scratch.