peter.king@LIGO.ORG - posted 03:09, Tuesday 12 April 2016 - last comment - 03:41, Tuesday 12 April 2016(26537)
PSL work
Transfer functions of the injection locking servo electronics were taken.
The previous measurements from when the PSL underwent acceptance testing
are posted in the DCC under
  https://dcc.ligo.org/DocDB/0100/E1300129/001/tf.pdf
That result listed the unity gain and phase margin as being 2.8 kHz and
57 degrees respectively.

With the previous setting of gain = -1.50V, the unity gain is ~8.5 kHz
with about 40 degrees of phase margin.  Setting the gain to -1.70V, upped
the unity gain to ~10 kHz.  This is consistent with the acceptance test
result from L1, which is in the DCC under
  https://dcc.ligo.org/DocDB/0068/E1100716/006/injection_locking_tf.pdf

Also attached is the oscilloscope image of the injection locking error
signal.