C. Cahillane I made a "calibration movie", or a gif of the entire O1 calibration for C01 and C02. The darkest line is the current systematic error, and the dashed lines are the current uncertainty. Kiwamu made the helpful suggestion that I leave a trace of previous calibrations. Previous calibrations are the light lines left behind from the dark trace. You can imagine these movies as a trace over the spectrograms from LHO aLOG 26535. I like this visualization of the high-frequency dither we see in our calibration. Also this gives a good impression of how much our cavity pole affects us in the C02 calibration movie, since the cavity pole is the only time-dependent parameter not corrected for in C02. For the LLO Calibration Movies, please see LLO aLOG 25647