Displaying report 1-1 of 1.
Reports until 18:26, Wednesday 13 April 2016
H1 CDS (DAQ, DCS)
david.barker@LIGO.ORG - posted 18:26, Wednesday 13 April 2016 (26586)
LDAS work completed, h1fw0 back, h1asc model restart

Dan completed the Q-Logic switch and SATA-BOY raid move from LSB to warehouse. The frame gap on h1fw0 is 12:01 - 17:58 PDT.

We installed Jenne's latest h1asc model and restarted the DAQ. h1fw1 did not start cleanly via monit and h1fw0 was having issues around the restart time. The framewriters did not sync-up with each other, maybe an issue in the time order of the asc and daq restarts. I did a second DAQ restart (with subsequent h1fw1 panic crash) which synced everything up. Moral of the story, if a fw is misbehaving, do not restart the DAQ until it is stable.