IM1, IM2, and IM3 now have a notification in DIAG_MAIN when alignment has shifted

The IM alignment shifts have caused locking issues, and so I asked TJ to add an alignment notification for IM1, IM2, and IM3 in DIAG_MAIN.

I've set the notification levels at:

These levels reflect roughly twice the drift in a recent 60 day trend.

Nominal alignment values in the notifications are:

IM3 yaw nominal value may need to be updated in about a month, since it has a sustained downward drift that was present through O1 and continues.

- TJ, Cheryl

Comments related to this report
cheryl.vorvick@LIGO.ORG - 12:30, Wednesday 20 April 2016 (26691)

To clarify:  

  • Limits on alignment shifts = smallest, based on how input alignment effects H1
  • Limits on alignment Notifications = larger that limits on alignment shifts, due to drift

Limits on alignment shifts:

  • IM1: +/-1urad
  • IM2: +/-5urad
  • IM3: +/-5urad
  • Alignment shifts that are at or above these levels need to be corrected

Limits on alignment Notifications must be larger:

  • IM1: +/-2urad
  • IM2: +/-10urad
  • IM3: +/-10urad

The Notifications are only intended to allert Operators and Commissioners to an IM alignment shift that may have happened during a time when the CR was not staffed.

What is always true regarding the IM alignments:

When HAM2 ISI trips, it continues to be necessary to trend IM1, IM2, and IM3 alignments to check for shifts that need to be corrected, regardless of the Notifications appearance or lack of appearance on DIAG_MAIN.