Displaying report 1-1 of 1.
Reports until 12:29, Wednesday 27 April 2016
H1 CDS (DAQ, SUS)
david.barker@LIGO.ORG - posted 12:29, Wednesday 27 April 2016 (26823)
h1omcpi, h1susitmpi model changes, DAQ restart

Tega, Ross, Dave WP5850

We added two Dolphin IPC senders on the h1omcpi model (running at 64kHz) and two corresponding receivers on h1susitmpi. These send the OMC DC_PD signals for A and B PDs. A new common part in PI_MASTER.mdl was created.

Both models were restarted, followed by a DAQ restart.

Displaying report 1-1 of 1.