Reports until 17:53, Wednesday 27 April 2016
H1 TCS
nutsinee.kijbunchoo@LIGO.ORG - posted 17:53, Wednesday 27 April 2016 (26836)
TCS CO2 power guardian nodes

Jamie, TJ, Nutsinee

Two new TCS guardian nodes have been created. They handle CO2X and CO2Y output power (by adjusting the rotation stages). MIN_POWER outputs minimum power to the optics (0 W). PRE_HEATING outputs 0.1W for CO2Y and 0.35 W for CO2X. And NOMINAL_LOCKED_CO2_LEVEL is outputing 0W at the moment but can easily be changed in the future. NOMINAL_LOCKED_CO2_LEVEL (CO2 output = 0W) is to be used at 20W IFO power.

I have tested PRE_HEATING and NOMINAL_LOCKED_CO2_LEVEL when everything is in a good state (CO2 laser on, no interlock tripped) and they seem to work as I hoped. Once I have a chance to test these states when things go wrong (no laser, interlock tripped) and see that they behave as expected I will make ISC_LOCK talk to it. The state is left at PRE_HEATING at the moment since we mostly stay at 2 W and 10W nowadays.

Images attached to this report