Displaying report 1-1 of 1.
Reports until 17:07, Wednesday 27 April 2016
LHO VE (CDS, VE)
patrick.thomas@LIGO.ORG - posted 17:07, Wednesday 27 April 2016 - last comment - 09:05, Thursday 28 April 2016(26831)
Forced X1 PT140 Cold Cathode on in Beckhoff
The X1 PT140 Pirani gauge is reading above the software interlock threshold to turn on the Cold Cathode gauge. Per Chandra's request I have bypassed the software interlock by forcing the variables in Beckhoff on h0velx (see attached screenshot).
Images attached to this report
Comments related to this report
kyle.ryan@LIGO.ORG - 09:05, Thursday 28 April 2016 (26849)
We may use the intermittent "bad" behavior of the pirani/cable/connection or whatever as an excuse to install the aLIGO wide range gauge sooner rather than later.  
Displaying report 1-1 of 1.