jason.oberling@LIGO.ORG - posted 12:23, Wednesday 25 April 2012 (2691)
IAS Pitch/Yaw Measurements
IAS: D. Cook, J. Oberling
SUS: B. Bland
Performed final pitch/yaw alignment of BSC08 ITMy this morning:
Pitch: 7.5 µrad down
Yaw: 87 µrad CCW
These are within our spec for mechanical alignment adjustments (±160 µrad pitch/yaw), therefore IAS is now done at BSC08 and will begin to transition to BSC06 this afternoon.