Reports until 18:39, Monday 02 May 2016
H1 CDS (CDS, ISC, PEM, SEI, SUS)
jeffrey.kissel@LIGO.ORG - posted 18:39, Monday 02 May 2016 - last comment - 12:00, Tuesday 03 May 2016(26930)
Creating target area softlinks for all SDF safe, down, and OBSERVE files; Committed to userapps repo.
J. Kissel

Continuing the work of Corey et al. have done cleaning up SDF files, (see LHO aLOG 26917), I've gone one level deeper to ensure that all snap files used in the target areas are soft links to locations in the userapps repo. 

There *is* a safe.snap for every front-end model / epics db, of which there are 129. Unfortunately, because they're human construction, there are less OBSERVE.snaps (112) and down.snaps (28). OBSERVE.snaps at least exist for every front-end model / epics db that existed during O1. However, weather station dbs, dust monitor dbs, and pi front-end models are new since O1, so OBSERVE.snaps don't exist for them. Further, down.snaps seem to have only been created for ISC models, the globally controlled SUS models, and the ISC-related beckhoff PLCs. We know the safe.snaps are poorly maintained, and sadly we haven't been in a configuration we'd call OBSERVE.snap worth in a long time, so they're also out of date. On top of all this, each subsystem seems to have a different philosophy about safe vs. down.

Daniel, Sheila, Jamie, and myself were discussing this on Friday, we'd come to the conclusion that it is far too difficult to maintain three different SDF files. If the SDF mask is built correctly, then there should be no difference between the "down" and "safe" state. The inventors of the "safe" state are the SEI and SUS teams because they have actuators strong enough to damage hardware. As such, they've designed the front-end models such that all watchdogs come up tripped and user intervention is required to allow for excitations. So, as the model comes up, it's already "safe" regardless of it's settings. Of course, even though the IFO is "down" at that starting point, we still want the platforms to be fully isolated. So, in that sense, for the ISIs "down" is the same as "OBSERVE." And again, if all settings that change via guardian are correctly masked out, then "safe" is the same as "down" is the same as "observe" and you only need one file. 

So, eventually -- we should get back to having only one file per subsystem. But this will take a good bit of effort to make sure that what's controlled via guardian is masked out of every SDF, and vice versa, that what is masked out of SDF *is* controlled by guardian. The temporary band-aid idea, will be at least to make sure that every model's down is the same as it's safe. Because Corey et al. put a good bit of effort into reconciling the down and safe.snap files today, I've copied all of the down.snap's over to the safe.snaps and committed them to the repo. I've not yet gone as far as to change the safe.snap softlinks to point to the down.snaps, but that will be next.

Anyways -- this aLOGs kinda rambling, because this activity has been disjointed, rushed, and sporadic, but I wanted to get these thoughts down and give an update on the progress. In summary, at least every safe, down, and OBSERVE.snap in the target area is a soft link to the userapps repo, and all of those files in the userapps repo are committed. More tomorrow, maybe.


Comments related to this report
corey.gray@LIGO.ORG - 12:00, Tuesday 03 May 2016 (26964)

Thanks for the write-up here!  A couple of comments/notes:

1)  Does every frontend really have a safe.snap?  I thought I could not find some safe.snaps for some of the ECAT (i.e. slow control) frontends.  Or is there a way for the SDF Overview medm to not display *all* SDF files?

2)  If we manage to get to ONE SDF file, what' will we name it?  Will we stay with "safe" since that's what the RCG calls out, or will we change it to a name more preferred (this was another subtle note I overheard you all discussing on Fri.)