Because we were focused on the QUAD-centric susaux model changes last month (alog 25313), we screwed up the DAQ channel lists for the HAM models (h1susauxh2, h34, h56) after a change to the master FOUROSEM library part. We turned the NOISEMONs for this library part into filter banks so they needed an _OUT in their channel names. I fixed these today for the 3 sus ham models and Dave recompiled. We have more work to do on these models as per existing ECRs. See attached for an example of how I've left these DAQ channel lists. Note, we still need to deal with the VOLTMONs and switch the T SIXOSEM library part Noisemons.
With Kissel, continued more cleanup work to remove VOLTMONs and add filterbanks to the NOISEMON and FASTIMONs of the h1susauxh2, 3h34, and h56 models. Will continue tomorrow morning to finish tweaking the DAQ channel lists of these. All under ECR E160003.