Reports until 16:58, Monday 02 May 2016
H1 CDS (DAQ)
david.barker@LIGO.ORG - posted 16:58, Monday 02 May 2016 (26939)
RCG 3.0 upgrade postponed until tomorrow

We discovered some build issues which meant we missed today's deadline to upgrade the CDS frontends and DAQ to RCG3.0. We are now ready for a second try tomorrow.

The main issue was tracked to a difference in the version of PERL running on the build machines, with h1build running 5.8.8 and l1build running 5.12.2. A condition statement in the perl module SUM.pm was performing a comparison with the return of a length() call with a null string ( eq "" ) which works with the later version but not with the older version. This line was changed to a numeric comparison ( == 0) which works for all versions.

Several other build issues:

Rolf has included the SUM.pm fix in the next tagged release RCG3.0.2

Betsy has some SUS changes she will install first thing Tuesday morning. After this we will do a clean build and install before shutting all systems down for the upgrade.