Reports until 19:56, Monday 02 May 2016
H1 SEI
patrick.thomas@LIGO.ORG - posted 19:56, Monday 02 May 2016 (26947)
BRS bad, tripped end Y ISI
Rich M., Patrick T.

I noticed that the end Y ISI and SUS watchdogs had tripped. I tried untripping them but they immediately tripped again. Rich found that the BRS was reporting bad. He turned off the sensor correction for RY and turned off the BRS correction to the ground seismometer. He left on the sensor correction for X. I untripped the watchdogs again and they remained untripped.