Finished SUSAUX model changes, closing out ECR 1200, E1600033

Today, I finished tweaking the DAQ channel data rates for the SUS HAM FASTIMONS which are all in the commissioning frames - Kissel and Jenne discussed upping some of these rates, especially at the lowest stage of the globally controlled SUSes.  Namely the rates per stage of SUS are as follows.

For MC2, PRM, SRM:

M1   256

M2   2048

M3   Full rate

 

For MC1, MC3, PR2, PR3, SR2, SR3:

M1   256

M2   2048

M3   2048

 

Pictures of examples of each type are attached.

 

I have compiled, with a "successful" message:

h1susauxh2

h1susauxh34

h1susaux56

 

I think this means we can closeout ECR 1200.  'Will work on that with Kissel.

Images attached to this report
Comments related to this report
betsy.weaver@LIGO.ORG - 09:19, Tuesday 03 May 2016 (26958)

Note, this bug used be ECR 1200, now on FRS it is apparently 4702.