Displaying report 1-1 of 1.
Reports until 15:55, Tuesday 03 May 2016
H1 ISC
jenne.driggers@LIGO.ORG - posted 15:55, Tuesday 03 May 2016 - last comment - 17:34, Tuesday 03 May 2016(26968)
Restored ALS EndY

I noticed that the Yend ALS laser was not hitting its input pointing QPDs.  While looking around, I saw that many beckhoff epics channels were zeros.  I used the SDF interface to load the down_160502_115544.snap epics database (i.e., the new way of doing a burt restore), and things immediately came back. 

This looks like it won't be necessary on the Xend.

Comments related to this report
aidan.brooks@LIGO.ORG - 17:34, Tuesday 03 May 2016 (26974)

The HWS camera and RCX CLINK were restored in the OFF state. I just restarted them:

aidan.brooks@cdsssh:~$ caput H1:TCS-ETMY_HWS_RCXCLINKSWITCH On

Old : H1:TCS-ETMY_HWS_RCXCLINKSWITCH Off

New : H1:TCS-ETMY_HWS_RCXCLINKSWITCH On

aidan.brooks@cdsssh:~$ caput H1:TCS-ETMY_HWS_DALSACAMERASWITCH On

Old : H1:TCS-ETMY_HWS_DALSACAMERASWITCH Off

New : H1:TCS-ETMY_HWS_DALSACAMERASWITCH On

Displaying report 1-1 of 1.