L2 noise off all 4 test masses and all 4 coils / and as bonus: BS M2 noise

See also alog 26948. I repeated the L2 noise measurements described in alog 26948 for ETMX L2 and ETMY L2, as well as BS M2. For completeness I also added the ITM noise to this log.

The measurement conditions are the same as in alog 26948 (Acq Off, LP On, small 3kHz length drive).

Conclusion: no suspicius noise on the L2s (or the BS M2).

 

Plots 1-5 (in that order): ETMX, ETMY, ITMX, ITMY, BS

Plot 6: projection of the noise for the four main test masses.

 

Remark: ETMY features a 10Hz line, as well as a smaller 30Hz line. They seems to be real, and they have a different strenghts in the 4 coils.

Images attached to this report
Comments related to this report
stefan.ballmer@LIGO.ORG - 20:47, Tuesday 03 May 2016 (26991)

For future reference and noise budget purposes I attached text files for all 5 noise measurements. Each file has 5 coilumns: frequency and coils 1-4

Non-image files attached to this comment