Reports until 14:27, Sunday 08 May 2016
H1 PSL
sheila.dwyer@LIGO.ORG - posted 14:27, Sunday 08 May 2016 - last comment - 08:32, Monday 09 May 2016(27065)
found laser off

It seems like the laser shut down at around 11 pm local time friday night after being on for about 14 hours.  Attached is a screenshot of the laser medm screen as it look now, and some trends, the first is 4 seconds around the time it shut down (2016-05-07 4:46:56 UTC). Of the channels I looked at the HPO watchdog (PSL-OSC_PWRDOGON?) and the LRA seem to be the first to go. The third screenshot shows the power outputs over the 14 hours the laser was on, along with the humidity trend.  The humitidty looked alarming at first, but the last attachment shows a 10 day trend where the humidity seems to fluctuate this much and more.

Images attached to this report
Comments related to this report
peter.king@LIGO.ORG - 08:32, Monday 09 May 2016 (27066)
Looks like the NPRO shut down too, for whatever reason - which is not obvious to me.