Reports until 10:45, Wednesday 11 May 2016
H1 SUS
betsy.weaver@LIGO.ORG - posted 10:45, Wednesday 11 May 2016 - last comment - 11:11, Wednesday 11 May 2016(27115)
Started SUS ETM charge measurements - turned on HV PS at ETMY

This morning I started the ETMX Charge measurement.  As Sheila mentioned in her log 27102 yesterday, I had to drive to Y-End in order to turn on the HV ESD drivers which had been flipped off presumably during Beckhoff chaos over the last week9??).  We also then found that the BIO HI/LO VOLTAGE and HI VOLT DISCONNECT medm switches were OFF when they should be ON.  The SDF for these, while looking at the DOWN state is now showing red and in the incorrect state.  This SDF is confusing to me, so will sort out with Jenne/Jeff K soon.  After switching all of this ON, I was able to run the ETMY SUS charge measurments.

Comments related to this report
betsy.weaver@LIGO.ORG - 11:11, Wednesday 11 May 2016 (27116)

Note, I was able to matlab process the data for both ETMx and ETMy using the controls login, I was not able to run the long trend script on this account.  THe situation is worse when I log in as my own user account betsy.weaver (where I don't seem to have permissions to run any scripts in the svn/SusSVN/sus/trunk/QUAD/Common/Scripts directory.

So, will have to beat the streets to get someone else to launch this plotting scripts....