BSC06 ETMy Yaw Alignment
IAS: J. Oberling
SEI: H. Radkins, J. Warner, G. Grabeel, E. Allwine

While Hugh & Co. were adjusting the ISI level we also went ahead an aligned the ETMy yaw.  It started at 1.2 mrad CCW (top-down view) and we left it at 30 µrad CCW; spec for HEPI yaw adjustment is 0 ± 160 µrad.  ETMy pitch is currently at 300 µrad down (desired pitch is 639 µrad down) so some adjustment there is necessary upon Travis's return next week.

Comments related to this report
hugh.radkins@LIGO.ORG - 16:08, Friday 27 April 2012 (2720)
Jason and I concluded the work with some level shots on the ISI Optical Table.  We took three shots on the optical table and see a range of 0.4mm with the highest point being right at design elevation of 1661.7mm above chamber zero.  This was shot with the HEPI floating and the ISI unlocked.