kiwamu.izumi@LIGO.ORG - posted 20:40, Friday 13 May 2016 - last comment - 13:37, Sunday 15 May 2016(27190)
ISS third loop closed

Evan, Kiwamu,

In this afternoon, we closed the ISS third loop which are meant to damp the arm power fluctuation.

We confirmed that it suppressed the common arm power fluctuation at around 0.5 Hz by 10 dB nominally. We tested this loop at various PSL power from 2 to 25 W. Further sophistication of the loop shape can be done if necessary.

 


[nominal settings]

[injection point changed]

The original plan was to inject the third loop signal to either TRANSFER1 or 2 input. However it turned out that they have seem to have a factor of 10 attenuation, we ran into a range issue where the DAC output and SR560 (which is meant as a dewthitening filter) saturated before getting to the nominal servo gain. We instead moved the injection point to the one for the second loop by disconnecting the second loop and plugging the third loop cable.

Also, there is a low-pass-ish response somewhere in the second loop injection path which let us put a lead filter in FM3.

[Instability at 25 W]

With a 25 W PSL, we see an instability that occured at 0.24 Hz. Similarly to the usual arm power instability at 0.4 - 0.5 Hz, it modulated the arm power, but the frequency seems to be a bit low and it coupled to the HARD mode. This instability seems to happen regardless of whether the third loop is closed or not. A possible source might be an unstable ASC loop. Currently  under investigation.

Images attached to this report
Comments related to this report
evan.hall@LIGO.ORG - 13:37, Sunday 15 May 2016 (27200)

The third loop signal now goes through an SR560 with an inversion, so the gain should now be +0.04 in the filter module.