Tega, Ross, Jim, Dave:
We installed new code for the models h1susitmpi, h1susetmxpi and h1susetmypi. The new code required a DAQ restart, which TEAM-PI obtained permission from TEAM-COMMISSIONING for this afternoon.
The purpose for the change was to make the code more efficient and claw back some CPU time on the h1susitmpi model which was running long (15-16uS for a 64k model). This was successful, it is now running in the 9-10uS range. ETMX is unchanged at 7uS, there is hint that ETMY is running one micro-second longer from 3uS to 4uS.