Displaying report 1-1 of 1.
Reports until 14:26, Tuesday 17 May 2016
H1 IOO (ISC)
nutsinee.kijbunchoo@LIGO.ORG - posted 14:26, Tuesday 17 May 2016 (27244)
PSL rotation stage calibration May 17th

I gathered some new data points from today and fine tuned the calculator. The requested power and measured power now agree within 1%. A 10-day minute trend of PMC transmitted power shows that the PSL power itself fluctuates on the daily basis which will throw off the calibration slightly. The calculator must be re-tuned based on the maximum PSL power going to the IMC, given that the minimum power angle doesn't change.

Images attached to this report
Displaying report 1-1 of 1.