Displaying report 1-1 of 1.
Reports until 14:25, Friday 20 May 2016
H1 CDS (PSL)
david.barker@LIGO.ORG - posted 14:25, Friday 20 May 2016 (27323)
cleared false filtermodule diff after ISS_SECONDLOOP_REF_SIGNAL_SERVO filter accidentally loaded

the h1psliss system was reporting a false difference in the filtermodules loaded vs the chans file. This was tracked to the rcg3.0 problem (reported https://alog.ligo-wa.caltech.edu/aLOG/index.php?callRep=27247) with repeating filters in the working file if a filter is loaded whose name is the core for other filters. In this case ISS_SECONDLOOP_REF_SIGNAL_SERVO was loaded which is the core name for ISS_SECONDLOOP_REF_SIGNAL_SERVOINF. After verifying that the diff being reported was solely due to multiple copies of the same filters, we performed a full filter load on h1psliss to clear the error. Since at all times the filters were being overwritten with identical filters, no runtime changes were made.