CDS maintenance summary

QUAD Master model change WP5899

Kiwamu, Betsy, Dave:

Kiwamu made a changed to QUAD_MASTER. All four quad models were rebuilt and restarted (h1susitm[x,y], h1susetm[x,y]

CAL model changes WP5894

Kiwamu, Dave:

All three calibration models were changed, built and restarted (h1calcs, h1calex, h1caley).

Vacuum Controls change for Mech Room IP1,3,8 WP5889

Patrick, Dave:

Beckhoff code for h0vacmr control of IP[1,3,8] changed. New EPICS database, autoBurt.req and DAQ ini files generated. This entails a channel name change, I have changed the running minute trend files. Still need to cover archived files.

Update NDS2 client code. WP5886

Jim B:

nds2 client code updated, please see earlier alog.

DMT Broadcaster channel change

Dave:

Changed the duotone channels in H0BROADCAST0.ini to reflect LLO names (use IN1 rather than OUT channels in filtermodule). This change went into effect when the DAQ was restarted.

New SUS PI models

Tega, Ross, Dave

New h1susitmpi, h1susetmxpi and h1susetmypi models were installed.

ADC card installed in h1oaf0 IO Chassis for NGN model

Dave, Jim:

We installed a 6th ADC card into h1oaf0's IO Chassis. This is a long-term-temporary card (will be removed post O2) which will provide the h1ngn model with 30 sensor channels. Powering down h1oaf0 meant that the following models were restarted: h1ngn, h1pemcs, h1oaf, h1tcscs, h1odcmaster, h1calcs.

The h1iopoaf0 model was edited to add the 6th ADC.

The h1ngn model was modified to use the new ADC.

In the IO Chassis we decided to locate the ADC between the DAC and DC power supply rather than group it with the other 5 ADC cards, This minimized the models which needed to be modifed to just 2.

Check 18bit DAC card in h1susb123 which failed its autocal

Dave, Jim:

Following the reboot of h1susb123, h1iopsusb123 reported that the first 18bit DAC card had failed its autocal. Today we restarted h1iopsusb123 three times, and each time the first DAC is reported to have failed autocal.

h1asc filter file loaded

Dave:

h1asc was showing a modified filter file. Investigation shows another repeated-filters problem (DHARD this time). I performed a full load.

Comments related to this report
david.barker@LIGO.ORG - 16:24, Tuesday 24 May 2016 (27362)

Additional Ion Pumps in MechRoom

Patrick, Dave:

on Tue afternoon Patrick added two new Ion Pumps (13 and 14) to h0vacmr. I rebuilt H0EDCU_VAC.ini and restarted the DAQ. The autoBurt.req file was also updated.