Evan G. and I have restarted CW hardware injections, using the old iLIGO actuation scheme, where the correction for the actuation function is done directly, frequency by frequency, for each of the 15 injected pulsars individually, without using a time-domain inverse actuation filter. That filter is now no longer in the path between H1:CAL-PINJX_CW and H1:CAL-PINJX_HARDWARE. We have verified that the new envelope of the H1:CAL-PINJX_HARDWARE channel is close to what it was before and that the spectral heights of the injected signals look about the same (we don't expect perfect agreement). The injections will be left running for at least 24 hours, to verify that the sidereal-day envelope agrees with what it was before, within expectation, and that same-sidereal-time spectral snapshots agree reasonably well. For reference, a new subdirectory O2test has been created in the hinj Details/pulsar/ directory for this test and the symlink RELEASE redefined to point to it. The only differences between the files in O2test and O1test are the addition of Evan's actuation function posted here and new in.N (N=0-14) command files with the makefakedata actuation argument turned on. Once we are satisfied the new injection actuation is working as intended, the svn directories will be updated. One other change I'd like to make is to use an actuation function file that takes into account the extra time delay for the excitation channel itself. Evan will consult with Jeff on approval for that swap.