During the laser shutdowns last night, we acquire the background values for the CO2 laser QPDs.
| X (counts) | Y (counts) | |
| QPD_A_SEG1 | 171 | -17.7 |
| QPD_A_SEG2 | -74.3 | 22.8 |
| QPD_A_SEG3 | -131.3 | 451.5 |
| QPD_A_SEG4 | 419.5 | -446.9 |
| QPD_B_SEG1 | -150.2 | -53.95 |
| QPD_B_SEG2 | 854 | -238.1 |
| QPD_B_SEG3 | 197.1 | 366.9 |
| QPD_B_SEG4 | 181.7 | 68.4 |
The following adjustments were made to CO2 QPD EPICS channels to enter (and activate) the offsets and to add in the correct coefficients in the PIT/YAW/SUM summing matrices
caput H1:TCS-ITMX_CO2_QPD_A_SEG1_OFFSET -171
caput H1:TCS-ITMY_CO2_QPD_A_SEG1_OFFSET 17.7
caput H1:TCS-ITMX_CO2_QPD_A_SEG2_OFFSET 74.3
caput H1:TCS-ITMY_CO2_QPD_A_SEG2_OFFSET -22.8
caput H1:TCS-ITMX_CO2_QPD_A_SEG3_OFFSET 131.3
caput H1:TCS-ITMY_CO2_QPD_A_SEG3_OFFSET -451.5
caput H1:TCS-ITMX_CO2_QPD_A_SEG4_OFFSET -419.5
caput H1:TCS-ITMY_CO2_QPD_A_SEG4_OFFSET 446.9
caput H1:TCS-ITMX_CO2_QPD_B_SEG1_OFFSET 150.2
caput H1:TCS-ITMY_CO2_QPD_B_SEG1_OFFSET 53.95
caput H1:TCS-ITMX_CO2_QPD_B_SEG2_OFFSET -854
caput H1:TCS-ITMY_CO2_QPD_B_SEG2_OFFSET 238.1
caput H1:TCS-ITMX_CO2_QPD_B_SEG3_OFFSET -197.1
caput H1:TCS-ITMY_CO2_QPD_B_SEG3_OFFSET -366.9
caput H1:TCS-ITMX_CO2_QPD_B_SEG4_OFFSET -181.7
caput H1:TCS-ITMY_CO2_QPD_B_SEG4_OFFSET -68.4
caput H1:TCS-ITMY_CO2_QPD_A_SEG1_SW1 8
caput H1:TCS-ITMY_CO2_QPD_A_SEG2_SW1 8
caput H1:TCS-ITMY_CO2_QPD_A_SEG3_SW1 8
caput H1:TCS-ITMY_CO2_QPD_A_SEG4_SW1 8
caput H1:TCS-ITMY_CO2_QPD_B_SEG1_SW1 8
caput H1:TCS-ITMY_CO2_QPD_B_SEG2_SW1 8
caput H1:TCS-ITMY_CO2_QPD_B_SEG3_SW1 8
caput H1:TCS-ITMY_CO2_QPD_B_SEG4_SW1 8
caput H1:TCS-ITMX_CO2_QPD_A_SEG1_SW1 8
caput H1:TCS-ITMX_CO2_QPD_A_SEG2_SW1 8
caput H1:TCS-ITMX_CO2_QPD_A_SEG3_SW1 8
caput H1:TCS-ITMX_CO2_QPD_A_SEG4_SW1 8
caput H1:TCS-ITMX_CO2_QPD_B_SEG1_SW1 8
caput H1:TCS-ITMX_CO2_QPD_B_SEG2_SW1 8
caput H1:TCS-ITMX_CO2_QPD_B_SEG3_SW1 8
caput H1:TCS-ITMX_CO2_QPD_B_SEG4_SW1 8
caput H1:TCS-ITMY_CO2_QPD_A_MTRX_3_1 1
caput H1:TCS-ITMY_CO2_QPD_A_MTRX_3_2 1
caput H1:TCS-ITMY_CO2_QPD_A_MTRX_3_3 1
caput H1:TCS-ITMY_CO2_QPD_A_MTRX_3_4 1
caput H1:TCS-ITMY_CO2_QPD_A_MTRX_1_1 1
caput H1:TCS-ITMY_CO2_QPD_A_MTRX_1_2 1
caput H1:TCS-ITMY_CO2_QPD_A_MTRX_1_3 -1
caput H1:TCS-ITMY_CO2_QPD_A_MTRX_1_4 -1
caput H1:TCS-ITMY_CO2_QPD_A_MTRX_2_1 1
caput H1:TCS-ITMY_CO2_QPD_A_MTRX_2_2 -1
caput H1:TCS-ITMY_CO2_QPD_A_MTRX_2_3 -1
caput H1:TCS-ITMY_CO2_QPD_A_MTRX_2_4 1
caput H1:TCS-ITMY_CO2_QPD_B_MTRX_3_1 1
caput H1:TCS-ITMY_CO2_QPD_B_MTRX_3_2 1
caput H1:TCS-ITMY_CO2_QPD_B_MTRX_3_3 1
caput H1:TCS-ITMY_CO2_QPD_B_MTRX_3_4 1
caput H1:TCS-ITMY_CO2_QPD_B_MTRX_1_1 1
caput H1:TCS-ITMY_CO2_QPD_B_MTRX_1_2 1
caput H1:TCS-ITMY_CO2_QPD_B_MTRX_1_3 -1
caput H1:TCS-ITMY_CO2_QPD_B_MTRX_1_4 -1
caput H1:TCS-ITMY_CO2_QPD_B_MTRX_2_1 1
caput H1:TCS-ITMY_CO2_QPD_B_MTRX_2_2 -1
caput H1:TCS-ITMY_CO2_QPD_B_MTRX_2_3 -1
caput H1:TCS-ITMY_CO2_QPD_B_MTRX_2_4 1
caput H1:TCS-ITMX_CO2_QPD_A_MTRX_3_1 1
caput H1:TCS-ITMX_CO2_QPD_A_MTRX_3_2 1
caput H1:TCS-ITMX_CO2_QPD_A_MTRX_3_3 1
caput H1:TCS-ITMX_CO2_QPD_A_MTRX_3_4 1
caput H1:TCS-ITMX_CO2_QPD_A_MTRX_1_1 1
caput H1:TCS-ITMX_CO2_QPD_A_MTRX_1_2 1
caput H1:TCS-ITMX_CO2_QPD_A_MTRX_1_3 -1
caput H1:TCS-ITMX_CO2_QPD_A_MTRX_1_4 -1
caput H1:TCS-ITMX_CO2_QPD_A_MTRX_2_1 1
caput H1:TCS-ITMX_CO2_QPD_A_MTRX_2_2 -1
caput H1:TCS-ITMX_CO2_QPD_A_MTRX_2_3 -1
caput H1:TCS-ITMX_CO2_QPD_A_MTRX_2_4 1
caput H1:TCS-ITMX_CO2_QPD_B_MTRX_3_1 1
caput H1:TCS-ITMX_CO2_QPD_B_MTRX_3_2 1
caput H1:TCS-ITMX_CO2_QPD_B_MTRX_3_3 1
caput H1:TCS-ITMX_CO2_QPD_B_MTRX_3_4 1
caput H1:TCS-ITMX_CO2_QPD_B_MTRX_1_1 1
caput H1:TCS-ITMX_CO2_QPD_B_MTRX_1_2 1
caput H1:TCS-ITMX_CO2_QPD_B_MTRX_1_3 -1
caput H1:TCS-ITMX_CO2_QPD_B_MTRX_1_4 -1
caput H1:TCS-ITMX_CO2_QPD_B_MTRX_2_1 1
caput H1:TCS-ITMX_CO2_QPD_B_MTRX_2_2 -1
caput H1:TCS-ITMX_CO2_QPD_B_MTRX_2_3 -1
caput H1:TCS-ITMX_CO2_QPD_B_MTRX_2_4 1