Reports until 19:22, Tuesday 31 May 2016
H1 ISC (SUS)
evan.hall@LIGO.ORG - posted 19:22, Tuesday 31 May 2016 (27464)
Top mass pitch and yaw damping improvements

Rana, Evan

The top mass pitch and yaw damping filters for the quads were inconsistent between different suspensions. We cleaned up and regularized the filters (in particular, by turning off the lower-Q "newboo" filter in one of the ETM pitch loops), and settled on the following configurations:

The step responses look reasonable (Q of 4 or so). We tuned the gains by increasing them until we saw oscillation, and then we backed off by 6 dB or so. The overall pitch loops are basically the same as before, while the yaw loops have 12 dB more gain.