Reports until 09:23, Wednesday 01 June 2016
H1 SEI
hugh.radkins@LIGO.ORG - posted 09:23, Wednesday 01 June 2016 (27475)
ETMY CPS--H3-- Health: Was iffy in Feb/March Now looks pretty good

FRS 4424 Alogs 25713 & 25820

The attached spectra suggests that the H3 performance is pretty indistinguishable from the other sensors and looks much better than the H3 sensor looked in March after some card swapping.  We ended up with the same board in place ultimately and have done nothing since.  I recommend we close 4424 and monitor.

Images attached to this report