Displaying report 1-1 of 1.
Reports until 09:53, Friday 03 June 2016
H1 CDS (SUS)
james.batch@LIGO.ORG - posted 09:53, Friday 03 June 2016 - last comment - 13:36, Friday 03 June 2016(27535)
Additional ADC added to h1susauxb123
An additional ADC was added to the h1susauxb123 I/O chassis.  The new card was added to the expansion board at bus 1-2, making it ADC1 in relation to the existing ADC cards.  All ribbon cables between the ADC and interface cards were rearranged with the exception of ADC0 so that none of the cables to the AA chassis needed to be swapped and the h1susauxb123 model doesn't need to be modified.
Comments related to this report
keith.thorne@LIGO.ORG - 10:06, Friday 03 June 2016 (27536)
Which ECR is this done under ( I assume it is the ITM ESD install)?
david.barker@LIGO.ORG - 11:19, Friday 03 June 2016 (27541)

I'm assuming it is covered by ECR E1600064 though it is not clear if that ECR shows the additional ADC channels for the sus-aux system needed to support the PI-ESD install on the ITMs. 

james.batch@LIGO.ORG - 13:36, Friday 03 June 2016 (27547)
I should have made it apparent that there are now 8 ADC cards installed in the h1susauxb123 I/O chassis. My original post omitted this important detail.  The newly installed card is ADC7.
Displaying report 1-1 of 1.