Displaying report 1-1 of 1.
Reports until 15:04, Friday 03 June 2016
H1 SUS
jeffrey.kissel@LIGO.ORG - posted 15:04, Friday 03 June 2016 (27554)
Beam Splitter (BSFM) Library Part Updated to Handle Newly Named TACQ Coil Driver Library Part
J. Kissel, D. Barker 

After the modifications to the HAM triple models to make coil driver filtering individually switchable (see LHO aLOG 27223), I had renamed the library parts in the 
/opt/rtcds/userapps/release/sus/common/models/STATE_BIO_MASTER.mdl
in order to clean up the confusion between the digital control of a modified triple-acquistion driver vs. and unmodified triple-acquisition driver.

However, in doing so, this renaming destroys the library link's reference in other models that use the specific block. This was identified by Dave who was trying to compile the BSFM model in prep for the power outage (which is the only *other* suspension type that uses the TACQ driver). As such, I copied in the newly renamed part from the library which restored the link. The model now compiles nicely, and has been committed to the userapps repository.