Reports until 15:58, Monday 06 June 2016
H1 CAL (AOS, CAL)
darkhan.tuyenbayev@LIGO.ORG - posted 15:58, Monday 06 June 2016 - last comment - 11:19, Tuesday 07 June 2016(27585)
Photon Calibrators after the power outage

Summary

On Friday, Pcals were turned off for the June 3-5 power outage (LHO alog 27558).

Details

After finding out that PcalY PDs are not measuring any power I went to the End-Y and checked following:

From this limited information and under the assumption that nothing is broken in the Pcal system, one of possible sources of the issue might be that control signals are not reaching the Pcal Interface module through an EtherCAT connector. The laser on/off and power level (5.0 V) signals should come through this interface (the Pcal Interface Chassis back-side board circuit is given in D1400149).

The issue in currently under investigation.

Comments related to this report
nutsinee.kijbunchoo@LIGO.ORG - 09:48, Tuesday 07 June 2016 (27610)

Filed FRS 5651

darkhan.tuyenbayev@LIGO.ORG - 11:19, Tuesday 07 June 2016 (27618)CAL

Filiberto, Darkhan,

Summary

  • PcalY is back up and operating in its nominal configuration.

Details

As it was reported in the original report above, there was an issue with turning on the PcalY laser and operating the shutter. The issue was discovered yesterday around 11am. After that I came back to get breaker circuits to proceed with investigations, but I found out that it is not needed.

At End Y there were issues with Beckoff system that were discovered independent from Pcal work. The Beckoff system feeds control signals to Pcal through EtherCAT cable into Pcal Interface Module. In the afternoon Filiberto went to EndY and replaced couple interface boards of the Beckoff system (see LHO alog 27583). After he let me know about the replacement work, I went back to EndY to turn on PcalY (needed to switch shutter control back to "remote" and double-check power switches on Pcal modules). Now the issue is resolved and PcalY is operating in its nominal configuration.