Displaying report 1-1 of 1.
Reports until 09:21, Thursday 09 June 2016
H1 SEI
edmond.merilh@LIGO.ORG - posted 09:21, Thursday 09 June 2016 (27664)
Sei siesmometer mass check - Monthly FAMIS #6075
Jim W has seen these results and is addressing them.
 
There are 41 T240 proof masses out of range ( > 0.3 [V] )!
ETMX T240 1 DOF X/U = 0.453 [V]
ETMX T240 1 DOF Y/V = 0.372 [V]
ETMX T240 1 DOF Z/W = 0.45 [V]
ETMX T240 2 DOF X/U = 0.464 [V]
ETMX T240 2 DOF Z/W = 0.939 [V]
ETMX T240 3 DOF X/U = 0.406 [V]
ETMX T240 3 DOF Y/V = 0.492 [V]
ETMX T240 3 DOF Z/W = 0.412 [V]
ETMY T240 1 DOF X/U = 0.427 [V]
ETMY T240 1 DOF Y/V = 0.478 [V]
ETMY T240 1 DOF Z/W = 0.51 [V]2016-06-09 09:19:28.361491
ETMY T240 2 DOF Y/V = 0.377 [V]
ETMY T240 3 DOF X/U = 0.526 [V]
ETMY T240 3 DOF Y/V = 0.443 [V]
ETMY T240 3 DOF Z/W = 0.452 [V]
ITMX T240 1 DOF X/U = 0.379 [V]
ITMX T240 1 DOF Y/V = 0.608 [V]
ITMX T240 1 DOF Z/W = 0.451 [V]
ITMX T240 2 DOF X/U = 0.586 [V]
ITMX T240 2 DOF Y/V = 0.566 [V]
ITMX T240 2 DOF Z/W = 0.668 [V]
ITMX T240 3 DOF X/U = 0.414 [V]
ITMX T240 3 DOF Y/V = 0.49 [V]
ITMX T240 3 DOF Z/W = 0.435 [V]
ITMY T240 1 DOF X/U = 0.357 [V]
ITMY T240 1 DOF Y/V = 0.404 [V]
ITMY T240 1 DOF Z/W = 0.446 [V]
ITMY T240 2 DOF X/U = 0.315 [V]
ITMY T240 2 DOF Y/V = 0.476 [V]
ITMY T240 2 DOF Z/W = 0.629 [V]
ITMY T240 3 DOF X/U = 0.496 [V]
ITMY T240 3 DOF Y/V = 0.417 [V]
BS T240 1 DOF X/U = 0.413 [V]
BS T240 1 DOF Y/V = 0.544 [V]
BS T240 1 DOF Z/W = 0.64 [V]
BS T240 2 DOF X/U = 0.555 [V]
BS T240 2 DOF Y/V = 0.552 [V]
BS T240 2 DOF Z/W = 0.549 [V]
BS T240 3 DOF X/U = 0.502 [V]
BS T240 3 DOF Y/V = 0.347 [V]
BS T240 3 DOF Z/W = 0.503 [V]
 
 
All other proof masses are within range ( < 0.3 [V] ):
ETMX T240 2 DOF Y/V = -0.143 [V]
ETMY T240 2 DOF X/U = 0.242 [V]
ETMY T240 2 DOF Z/W = 0.287 [V]
ITMY T240 3 DOF Z/W = 0.049 [V]
 
There are 1 STS proof masses out of range ( > 2.0 [V] )!
STS EY DOF X/U = -2.054 [V]
 
 
All other proof masses are within range ( < 2.0 [V] ):
STS A DOF X/U = 0.0 [V]
STS A DOF Y/V = -0.0 [V]
STS A DOF Z/W = -0.0 [V]
STS B DOF X/U = 0.118 [V]
STS B DOF Y/V = -1.274 [V]
STS B DOF Z/W = -0.166 [V]
STS C DOF X/U = -0.0 [V]
STS C DOF Y/V = -0.0 [V]
STS C DOF Z/W = -0.0 [V]
STS EX DOF X/U = -0.224 [V]
STS EX DOF Y/V = 0.616 [V]
STS EX DOF Z/W = 0.009 [V]
STS EY DOF Y/V = 0.311 [V]
STS EY DOF Z/W = 1.665 [V]
 
Displaying report 1-1 of 1.