Reports until 16:17, Friday 04 May 2012
H2 SEI
vincent.lhuillier@LIGO.ORG - posted 16:17, Friday 04 May 2012 (2767)
ISI-BSC8 - Transfer functions after reinstalling the QUAD

Last night, a set of transfer functions was measured on ISI-BSC8 (the first time since the QUAD was reinstalled). The plant is unchanged and instruments don't show abnormal behavior. However, we can notice a couple of new resonances probably from the QUAD (17.2Hz and 26Hz) on the stage 2 transfer functions (see attachment).