Displaying report 1-1 of 1.
Reports until 14:15, Thursday 09 June 2016
H1 SEI (GRD)
thomas.shaffer@LIGO.ORG - posted 14:15, Thursday 09 June 2016 (27672)
New Coner Station SEI Configuration nodes

Added new SEI configuration Guardian nodes to all of the corner station chambers except HAM1 (soon). For the CS BSCs the code is almost identical to what is ran at the end stations, but with the BRS checks removed. The HAM config nodes are a bit different, as they do not change the blends, only sensor correction.

In the near future there will be a SEI configuration manager that can change all of the chamber configurations at once. This will let us prep the IFO for incoming earthquakes or change the configuration for different environments.

Updated Guardian Overview shot attached.

WP#5907

Images attached to this report
Displaying report 1-1 of 1.