While I was checking through the list of running nodes, I noticed that there were a total of 5 TCS nodes. It seems that the old TCS_ITMX diagnostic node was still running, but no one knew since it was not on the overview or anywhere else. Since the newer TCS_ITMX_CO2 node has replaced this one, I destroyed the node after confirming with Nutsinee.
DAQ EDCU was briefly GREEN until this node was removed, now back to PURPLE.