SUS AI chassis mislabelled outputs as inputs

The suspension anti-imaging chassis (D1100815) has a mislabelling on it's front panel.  It has three outputs on the front panel but they are labeled "IN 1-6", "IN 7-12", and "IN 13-16".

Furthermore, the actual schematic for the AI interface board also lists the channels in the connectors as inputs.

This is a project-wide issue, not specific to H2, but I discovered it in the H2 EY electronics rack, so I'm reporting it here.

The schematic and front panel drawings should obviously be fixed, but I also really think we should replace the panels on all the manufactured units, including the ones that are deployed.  It's confusing and potentially dangerous to label outputs as inputs. 