sheila.dwyer@LIGO.ORG - posted 00:24, Tuesday 14 June 2016 (27715)
AS45I signals for SRM control

Evan, Sheila

Earlier today we had several locklosses while trying to engage the soft loops which may have been because SRM was uncontrolled and the POP90 power increased.  

We searched for a better error signal for a while tonight, we looked at dither SRM and demodulating DARM (low SNR), demodulating SRCL (good signal but a large offset), POPX, some REFL WFS.  

Finally we decided to try AS45I, where we had a reasonable signal with a zero crossing that gave us good sideband buildups for both pit and yaw.  For pit we are using 1*ASA45I +0.76*ASB45I, while for yaw we are using ASA45I+ASB45I.  The guardian is engaging these with a gain of -300 in SRC_ASC, which has worked once.  It allowed us to turn on the soft loops and corrected the sideband buildups.  