Reports until 13:23, Tuesday 14 June 2016
H1 ISC
sheila.dwyer@LIGO.ORG - posted 13:23, Tuesday 14 June 2016 (27720)
Increase power lockloss

I looked at last night's increase power lockloss, and can see that the lock broke right when the IMC common mode board gain slider moved. (plot attached).  For now I've changed the gain adjust function in the IMC guardian to make 2dB steps instead of 1dB. 

Images attached to this report