Reports until 14:06, Tuesday 14 June 2016
H1 SUS
filiberto.clara@LIGO.ORG - posted 14:06, Tuesday 14 June 2016 (27722)
ETMX PUM Chassis - RMS Reset

Modified the PUM Chassis by connecting pin 2 and pin 18 on the binary input DB37 connector. This was to address the issue of the binary RMS reset not working. See alog 27633. We confirmed this modification was already done at EY. Next Tuesday we will need to verify the ITM units have this modification.

We also confirmed that R111 had the correct value of 100K on all four channels.